Your roadmap · आपका रोडमैप
- 1
Admission & first meetingप्रवेश और पहली मुलाकातEnquire at your nearest NDSS centre, meet the teacher, fix the batch time and get your study material.
- 2
Part 1 of the syllabusपाठ्यक्रम भाग 1Unit-wise coaching with notes and doubt classes.
Unit 1: Symmetrical FaultsUnit 2: Symmetrical Components and Unsymmetrical FaultsUnit 3: Load Flow Studies
- 3
Part 2 of the syllabusपाठ्यक्रम भाग 2Unit-wise coaching with notes and doubt classes.
Unit 4: Power System StabilityUnit 5: Economic Operation
- 4
Unit tests & assignmentsयूनिट टेस्टRegular tests in the university / board pattern.
- 5
Semester 6 exam (university / board)विश्वविद्यालय / बोर्ड परीक्षाPrevious papers and full revision before the exam.
- 6
Online tests & resultऑनलाइन टेस्ट और रिज़ल्टTake the tests online; your marks and result show in your student login and at the centre.
Syllabus · पाठ्यक्रम
1 subject · 5 chapters · 27 topics
01Unit 1: Symmetrical Faults
5 topics+
- Impedance and reactance diagrams
- Transients on a transmission line
- Short circuit of an unloaded synchronous machine: subtransient, transient and steady-state reactances
- Short-circuit current and fault MVA
- Current-limiting reactors
02Unit 2: Symmetrical Components and Unsymmetrical Faults
6 topics+
- Symmetrical components and the a-operator
- Sequence impedances and networks of generators, transformers and lines
- Single line-to-ground fault
- Line-to-line fault
- Double line-to-ground fault
- Faults through impedance
03Unit 3: Load Flow Studies
6 topics+
- Bus classification: slack, PV and PQ
- Formation of Y-bus
- Load flow equations
- Gauss-Seidel method
- Newton-Raphson method
- Fast decoupled load flow
04Unit 4: Power System Stability
5 topics+
- Steady-state, transient and dynamic stability
- Swing equation and inertia constant
- Power-angle curve
- Equal-area criterion and critical clearing angle
- Factors affecting and methods of improving stability
05Unit 5: Economic Operation
5 topics+
- Input-output and incremental cost curves
- Economic dispatch neglecting losses
- Transmission loss formula and B-coefficients
- Economic dispatch including losses and penalty factor
- Unit commitment (introduction)
About this course
You will be able to
- Calculate symmetrical fault currents and fault MVA using per-unit reactance diagrams
- Analyse LG, LL and LLG faults using symmetrical components
- Form the bus admittance matrix and solve load flow by Gauss-Seidel and Newton-Raphson methods
- Apply the swing equation and equal-area criterion to stability problems
- Solve economic dispatch problems with and without transmission losses
Who it is for
- B.Tech Electrical Engineering students of Semester 6 under AKTU
- Students preparing for AKTU sessional tests, the end-semester examination and GATE power systems
What you need
- Power System-I and Electrical Machines-II
Online tests & result
Practice and unit tests online; marks and result show in your student login and at the centre.
Student login →
Questions
Which syllabus is followed?
The current AKTU (Dr. A.P.J. Abdul Kalam Technical University, Lucknow) B.Tech syllabus of Power System-II (Electrical Engineering, Semester 6). If your university or college follows a different syllabus, the centre teaches from your own university syllabus.
How is the subject examined?
AKTU assesses it through sessional tests, assignments and attendance, and an end-semester university examination; the centre covers every unit with theory, derivations and numericals.
Are previous-year questions practised?
Yes. Unit-wise AKTU previous-year questions, short-answer questions and the test series are solved in class.